Front Panel Overlays for Different Languages

Front panel overlays, which have translations for the English front panel
keys and label text, are available in 10 languages. The appropriate overlay
is included when the localization option is chosen at time of purchase.
To install a front panel overlay:
1 Gently pull on the front panel knobs to remove them.
2 Insert the overlay's side tabs into the slots on the front panel.
Agilent InfiniiVision 4000 X-Series Oscilloscopes User's Guide
USB Host ports
These ports are for connecting a USB mass storage device, printer,
mouse, or keyboard to the oscilloscope.
Connect a USB compliant mass storage device (flash drive, disk drive,
etc.) to save or recall oscilloscope setup files and reference waveforms
or to save data and screen images. See
(Setups, Screens, Data)," starting on page 307.
To print, connect a USB compliant printer. For more information about
printing see
You can also use the USB port to update the oscilloscope's system
software when updates are available.
You do not need to take special precautions before removing the USB
mass storage device from the oscilloscope (you do not need to "eject"
it). Simply unplug the USB mass storage device from the oscilloscope
when the file operation is complete.
CAUTION:
USB host port. Use the device port. A host computer sees the
oscilloscope as a device, so connect the host computer to the
oscilloscope's device port (on the rear panel). See
Settings"
There is a third USB host port on the back panel.
EXT TRIG IN
External trigger input BNC connector. See
connector
page 208 for an explanation of this feature.
Waveform
Built-in, license-enabled 2-channel waveform generator can output
generator
arbitrary, sine, square, ramp, pulse, DC, noise, sine cardinal, exponential
outputs
rise, exponential fall, cardiac, or Gaussian pulse waveforms on the
Gen Out 1 or Gen Out 2 BNC connectors. Modulated waveforms are
available on WaveGen1 except for arbitrary, pulse, DC, and noise
waveforms. Press the [Wave Gen1] or [Wave Gen2] keys to set up the
waveform generator. See
page 285.
Chapter
19, "Print (Screens)," starting on page 321.
Do not connect a host computer to the oscilloscope's
on page 327.
Chapter
17, "Waveform Generator," starting on
Getting Started