5.19 Resetting parameters to the factory settings

Preconditions:
• The machine is in programming mode; the LED in the Ready button is
1. Press the Memory button for 6 s.
2. Select parameter number U098 using the +/- Program buttons.
3. Press the Ready button.
4. Enter the function value 1 with the +/- Function buttons.
5. Press the Selection button.

5.20 Editing sewing patterns externally

5.20.1 MS Excel or text editor

Sewing patterns can be created and edited externally on a PC, e.g. using
MS Excel or a text editor.
Fig. 12: Example of sewing pattern
32
unlit.
The LED in the button is lit.
The controller beeps 1x. If the controller beeps 3x, the reset was unsuc-
cessful.