To Begin Scrubbing; Priming Pump - Windsor Chariot iScrub CSX24 Operating Instructions Manual

Hide thumbs Also See for Chariot iScrub CSX24:
Table of Contents

Advertisement

Operations

To Begin Scrubbing

When operating the machine around people, pay
close attention for unexpected movement. Use
extra caution around children.
Flammable liquids and/or reactive metals can
cause explosions or fire! Do not pick up.
1. Stand on the operator platform. Throttle pedal
must be in neutral position.
2. Turn machine power on.
3. Press the Drive Reset / Directional Control Switch,
selecting the desired travel direction.
4. Position the function control knob to the desired
operation. The brush motors will start, the scrub
deck will lower, the solution will begin to flow, the
squeegee will lower to the floor and the vacuum
motors will start.
5. Drive machine forward to begin scrubbing.
NOTE: Shut machine off immediately if water or foam
is expelled from the machine.
NOTE: Solution flow is automatically shut off when
brush motors stop. When brush motors are
activated, flow automatically resumes.
22

Priming Pump

If the solution system has gone dry or has been unused
for a period of time, it may be necessary to follow the
pump priming procedure.
1. Fill solution tank.
2. Loosen, but do not completely remove the strainer
bowl. Solution should flow out of the strainer. If it
does not, check the strainer screen inside the solu-
tion tank. Insure it is clear of debris. Tighten the
strainer bowl.
3. Disconnect the squeegee hose from the recovery
dome.
4. Begin normal scrubbing. Solution flow should
begin within 2 minutes.
5. Connect squeegee hose to recovery dome.
86317500 CHARIOT SCRUBBER