Operator Safety Instructions Read the instruction manual before operating this machine. Operate this machine only from the rear of machine. Use caution when operating the machine on a ramp or incline. Do not turn or leave this machine unattended on a ramp or incline. Machine can cause an explosion when operated near flammable vapors and materials.
Page 3
I‘ ‘I SQUEEGEE SOLUTION MAIN BATTERY SOLUTION VACUUM BRUSH SCRUB DECK LIFT LEVER CONTROL SWITCH CONOlTlON “ON” “ON” LIGHTED “ON” LIGHTED LIFT LEVER LEVER LIGHT LIGHT SWITCH SWITCH OPERATOR CONTROL HANDLE 1. Raises and lowers squeegee assembly. 2. Controls flow of cleaning solution to floor. 3.
MACHINE PREPARATION CLEAN I N G SO LUTlO N OPERATING MACHINE WITH ACCESSORY TOOL BATTERIES 1 . Fill machine with hot water and add cleaning chemical at the proportion floor tool for wet pick-up can be 1 . Install batteries and connect battery noted on the container.
3. Keep the battery electrolyte at th$ 4. Check motor brushes. When worn to correct level approximately 114 318” replace both brushes. below bottom of filler tube of each cell. Distilled water should be added, as needed, AFTER charging cycle. WARNING: Do not allow electrolyte level to drop below the tops of the plates.
The warranty is in lieu of all warranties, expressed or Implied, and releases Windsor from all other obligations and liabilities. It is applicable only in the U.S.A., Canada, Australia, and New Zealand.
Page 7
TANKS, VAC & FRAME TANKS, VAC FRAME PART NO. DESCRIPTION PART NO. DESCRIPTION PART NO. DESCRIPTIOM 70020 Scr, 1/4-20 x 112 HHMS 57047 Nut, 1/4-20 Ny-Lock 61181 Panel, Rear 73427 Float 87090 Washer, 1/4 Flat 67227 Rod, Vac Float 70010 Scr, 1/4-20 x 1.5 HHCS 73423 Screen, Float...
TROUBLE-SHOOTING GUIDE PROBLEM PROBABLE CAUSE CORRECTIVE ACTION No power. Battery cables corroded 1. Clean battery cable clamps and battery terminals. at battery terminals. 2. Check voltage at points A and B. Voltage should be 22/26 VDC. Faulty main switch. 1. Check voltage at points and C.