Emptying and Cleaning Tanks

1. Park the machine next to a floor drain. Drain hoses
are at the front of the machine.
2. Turn the machine power off.
RECOVERY TANK
1. Remove the recovery tank dome. Pull the large
drain hose from the mounting pocket. Unscrew
cap, then lower hose in direction of the drain. Do
not stand in front of end of hose. Recovered solu-
tion will come out with force.
2. Flush the recovery bag out with clean water. Do not
use water hotter than 140°F (60°C) to clean tank.
Damage may occur.
3. Clean debris from dome basket.
4. Clean off the float shut-off system and inspect for
free movement of float. The float shut-off system is
located in the rear of the recovery tank.
5. Replace the drain cap and secure drain hose under
tank.Replace the drain cap and secure drain hose
to front of tank.
6. If machine is to be stored, leave the recovery tank
dome off, or propped open.
24
SOLUTION TANK
RECOVERY
TANK DOME
1. Remove the recovery tank dome.
2. Pull the solution drain hose from its mounting
pocket. Unscrew the cap, then lower hose in direc-
tion of drain.
3. Remove the solution tank lid.
4. Flush the solution tank out with clean water and
run several gallons of clean water through sys-
tems. Do not use water hotter than 140°F (60°C) to
clean tank. Damage may occur.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.