Post Error Messages - HP Z800 - Workstation - 6 GB RAM Maintenance And Service Manual

Hp z800 workstation maintenance and service guide
Hide thumbs Also See for Z800 - Workstation - 6 GB RAM:
Table of Contents

Advertisement

POST error messages

The Power-On Self Text (POST) is a series of diagnostic tests that runs automatically when the
workstation is powered on.
Audible and visual messages occur before the operating system starts if the POST encounters a
problem. POST checks the following items to ensure that the workstation system is functioning properly:
Keyboard
DIMMs
Diskette drives
All mass storage devices
CPUs
Controllers
Fans
Temperature sensors
Cables (front/rear panels, audio, and USB ports)
The table shown next describes the POST error messages.
Table 6-10
Screen message
101—Option ROM Checksum
Error
102—System Board Failure
110—Out of memory space for
option ROMs
162—Systems Options Error
163—Time and Date Not Set
218 Chapter 6 Diagnostics and troubleshooting
POST error messages
Probable cause
System ROM checksum.
DMA, timers, and so forth, might be set
improperly or might be defective.
Option ROM for a device could not run
because of memory constraints.
Invalid time or date in
configuration memory.
RTC battery might need
replacement.
CMOS jumper might not be
properly installed.
Recommended action
Verify the correct ROM:
1.
Flash the ROM, if needed.
2.
If an expansion card was recently added, remove
it to find out if the problem remains.
3.
Clear CMOS. If the message disappears, there
might be a problem with the expansion card
4.
Replace the system board.
1.
Clear the CMOS.
2.
Remove the expansion boards.
3.
Replace the system board.
Run the Computer Setup (F10) Utility to disable
unneeded option ROMs, and to enable ACP0/USB
Buffers at Top of Memory.
1.
Set the date and time from the Control Panel or in
the Computer Setup (F10) Utility (depending on
the operating system).
2.
If the problem persists, replace the RTC battery.
ENWW