Check Burner Manifold Pressure; Annual/Periodic System Inspection; Fryer - Frymaster OCF30 Series Installation & Operation Manual

Oil conserving gas fryer
Hide thumbs Also See for OCF30 Series:
Table of Contents

Advertisement

3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any
obstruction.
4. Remove the wire and blow through the tube to ensure it is clear.
5. Reinstall the tube and bend it so that the opening is pointing downward.

5.6.2 Check Burner Manifold Pressure

This task should be performed by qualified service personnel only. Contact your
FAS to arrange this service.
5.7

Annual/Periodic System Inspection

This appliance should be inspected and adjusted periodically by qualified service personnel as
part of a regular kitchen maintenance program.
Frymaster recommends that an Factory Authorized Servicer inspect this appliance at least
annually as follows:

5.7.1 Fryer

• Inspect the cabinet inside and out, front and rear for oil.
• Verify that the flue opening is not obstructed by debris or accumulations of solidified oil.
• Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.)
are in good condition and functioning properly. Inspect all gas connections for leaks and verify
that all connections are properly tightened.
• Verify that the burner manifold pressure is in accordance with that specified on the appliance's
rating plate.
• Verify that the temperature and high-limit probes are properly connected, tightened and
functioning properly, and that probe guards are present and properly installed.
• Verify that component box components (i.e. controller, transformers, relays, interface boards,
etc.) are in good condition and free from oil and other debris. Inspect the component box wiring
and verify that connections are tight and that wiring is in good condition.
• Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and
functioning properly.
• Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in
serviceable condition.
• Verify that wiring harnesses and connections are tight and in good condition.
DANGER