Checking The Burner Manifold Gas Pressure - Frymaster H50 Series Service And Parts Manual

Table of Contents

Advertisement

1.4

Checking the Burner Manifold Gas Pressure

1. On non-CE fryers, ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly.
Typical Non-CE
Valve Assembly
2. Insert the fitting for a gas pressure-measuring device into the pressure tap hole.
3. On non-CE fryers only, place the gas valve in the ON position.
4. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for
at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table found on the following page. The tables list the burner manifold gas
pressures for each of the gas types that can be used with this equipment.
Honeywell
ON
OFF
Pressure Tap Plug
1-5
Typical CE Valve
Assembly

Advertisement