2. After all oil has drained from the pot, rotate the
Rear Flush handle to the ON position to activate
the pump. There may be a slight delay before
the pump activates.
3. As the filtering progresses, the computer will display the time remaining. When the filtering
time has elapsed, FILTER will flash in the display.
4. When FILTER flashes in the display, close the
drain valve and allow the frypot to refill.
5. When the filter pan has emptied, bubbles will
appear in the frypot. Allow the bubbling to
continue 15-20 seconds to purge all cooking oil
from the oil return lines, then rotate the Rear
Flush handle to the OFF position to stop the
pump.