alarm continues flashing. All functions return when the frypot temperature is within 15°F (8°C) of
the programmed setpoint.
Probe Failure Indication
If the temperature probe fails, the display will flash PROBE FAILURE and an audible alarm will
sound. To cancel the alarm, turn the computer OFF. In split-vat fryers, turn off the side in which the
failure occurred. If a probe fails during the high-limit test, PROBE FAILURE is displayed.
NOTE: If the temperature probe fails in the left side of a split-vat, that side cannot be turned back
ON once it has been turned OFF.
3.6
M-100B™ Computer Set-Up and Programming Instructions
The M-100B computer has three modes of operation. In addition to the Cooking Mode, which was
discussed in Sections 3.3 and 3.4, there is a Setup Mode and a Programming Mode. (The cooking
mode is the computer's default mode – when the computer is turned on, it comes up in the cooking
mode.)
In the Setup Mode, the operator can:
• change the computer's display language
• configure the computer for use on gas fryers
• configure the computer for use on either a full-vat or a split-vat fryer
• specify how the computer displays product names and temperatures
• calibrate computer temperature to actual frypot temperature
• activate or deactivate the frypot BOIL OUT feature
In the Program Mode, the operator can:
• reset the computer to the factory default settings
• change the shake, pull, and QA (hold) times for menu items
• change the cooking temperature setpoints for menu items
• add products and cooking parameters to the two test menus
• suppress a duty function in a menu item
• turn the display of a menu item in the factory-programmed menu on or off
• display usage information that is automatically recorded by the computer