Virtual Router Deployment Considerations; Assigning Vrrp Virtual Router Id; Configuring The Switch For Tracking - Nortel Alteon OS 42C4911 Application Manual

Nortel 10gb ethernet switch module for ibm bladecenter version 1.0
Table of Contents

Advertisement

Virtual Router Deployment Considerations

Review the following issues described in this section to prevent network problems when
deploying virtual routers:

Assigning VRRP Virtual Router ID

Configuring the Switch for Tracking

Assigning VRRP Virtual Router ID
During the software upgrade process, VRRP virtual router IDs will be automatically assigned
if failover is enabled on the switch. When configuring virtual routers at any point after
upgrade, virtual router ID numbers (/cfg/l3/vrrp/vr
virtual router ID may be configured as any number between 1 and 255.
Configuring the Switch for Tracking
Tracking configuration largely depends on user preferences and network environment. Con-
sider the configuration shown in
the network:
Switch 1 is the master router upon initialization.
If switch 1 is the master and it has one fewer active servers than switch 2, then switch 1
remains the master.
This behavior is preferred because running one server down is less disruptive than bring-
ing a new master online and severing all active connections in the process.
If switch 1 is the master and it has two or more active servers fewer than switch 2, then
switch 2 becomes the master.
If switch 2 is the master, it remains the master even if servers are restored on switch 1 such
that it has one fewer or an equal number of servers.
If switch 2 is the master and it has one active server fewer than switch 1, then switch 1
becomes the master.
42C4911, January 2007
Figure 13-5 on page
228. Assume the following behavior on
Alteon OS Application Guide
/vrid) must be assigned. The
#