Electrical; Ambient; Plumbing; Ventilation And Service Clearances - Follett Symphony 25HI400A Installation & Service Manual

Ice and water dispensers
Table of Contents

Advertisement

Electrical

115V, 60Hz, 1 phase, 14.0 amps. Connect to dedicated 20 amp circuit, fuse or breaker.
Note: It is preferred that circuit be protected by a GFCI.
Furnished with 7 ft (2m) power cord with a 90° NEMA hospital grade 5-20 plug.

Ambient

Air temp
Water temp
Water pressure

Plumbing

Dispenser drain
Water inlet
Condenser inlet
Condenser outlet
Note: Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard-piped
and insulated. Maintain at least 1/4" per foot (20mm per 1m run) of slope on horizontal runs.
• Do not block left side air intake or right side air exhaust
Ventilation and service clearances
Required for ventilation
Suggested for service

Uncrated weight

25/50CI400A/W (countertop)
25/50HI400A (wall mount)
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
Maximum
100 F/38 C (Best performance below 80 F/27 C)
90 F/32 C (Best performance below 70 F/21 C)
70 P.S.I.
Connections – 25/50CI400A/W
All – 3/4" FNPT
All – 3/8" FNPT
Water-cooled – 3/8" FNPT
Water-cooled – 3/8" FNPT
CAUTION
Air-cooled
3" (77mm) each side
12" (305mm) top,
6"(153mm) left side
215 lbs (98kg)
230 lbs (105kg)
Minimum
50 F/10 C
40 F/4 C
10 P.S.I.
Rough-ins – 25/50HI400A/
Air-cooled – 3/4" FNPT
All – 1/2" FNPT
N/A
N/A
Water-cooled
N/A
12" (305mm) top
5