Disassembly And Replacement Instructions; Dispense Wheel Removal And Installation; Drive Bar Removal; Wheel Motor Assembly Removal - Follett Symphony 25HI400A Installation & Service Manual

Ice and water dispensers
Table of Contents

Advertisement

Disassembly and replacement instructions

Dispense wheel removal and installation
1. Remove all ice from storage area of dispenser.
2. Remove center thumb nut from dispense wheel.
3. Remove thumb nuts holding baffle inside bin and
remove baffle.
4. Tilt rear of wheel up and lift off motor drive shaft.
5. After reinstalling wheel, secure baffle loosely with
thumb nuts, but do not tighten.
Fig. 12
baffle
dispenser
front
side view wheel section
6. Place a 1/16" (2mm) spacer against wheel and
allow baffle to drop until it touches spacer (Fig. 12).
7. Tighten thumb nuts and remove spacer.
Drive bar removal
1. Remove dispense wheel from dispenser
(see above).
2. Pull drive bar out of its channel in bottom of wheel.
Wheel motor assembly removal
1. Disconnect power.
2. Remove top cover and dispense wheel.
3. Slide icemaker out of dispenser as described on
page 16, icemaker removal. Icemaker does not
need to be removed completely if there is sufficient
clearance to access the dispenser motor through
the right louvered panel.
4. Disconnect wires on motor.
5. Remove four bolts (7/16" socket) holding motor
assembly to bottom of dispenser.
6. Remove motor assembly.

Ice transport tube replacement

• Tubing must be supplied by Follett Corporation
1. Disconnect power. Remove top and partially slide
icemaker out of dispenser as described on page 16.
2. Disconnect end of tube from icemaker.
14
1/16" (2mm)
spacer
CAUTION
3. Disconnect existing ice tube from engaging pin on
transport tube bracket in ice storage bin and pull
tube up through dispenser chase.
Fig. 13
ice level control stat
capillary tube
ice tube mounting bracket
3/16" (5mm) ice tube hole
4. Run the new ice transport tube down through chase
making sure that the end with the 3/16" (5mm) hole
is in the bin (Fig. 13).
Fig. 14
.3/16" (5mm)
dia. hole
Section A – A
1"
(26mm)
A
A
5. Push the 3/16" (5mm) hole near end of tube into pin
on ice tube bracket (Fig. 14).
6. Reinstall insulation
Fig. 15
7. Heat end of transport tube in cup of 160 F (71 C)
hot water to soften (Fig. 15).
8. Slip supplied hose clamp onto tube and push
tube onto compression nozzle on exit port of
evaporator. Do not twist tubing when securing to
evaporator.
9. Secure tube on port with hose clamp, being sure
that clamp is positioned on evaporator side of
nozzle flange.
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
engaging pin
1"
ice tube
(26mm)

Hide quick links: