Diagnostic sequence – Stage 7
The 20 minute error LED (20M) is on, indicating that the control board has sensed an over-torque condition (above
3 AMPS on the gearmotor). The 20M LED remains on for 20 minutes after an over-torque condition has occurred.
The icemaker remains off as long as the 20M LED is on. When the 20M LED goes off, the control board will try to
go through a normal start-up sequence. The WTR LED remains on as long as the water sensor in the float reservoir
senses water.
INPUT
POWER
G
B
W
COMPRESSOR
C
T.O.L.
RED
WHITE
WHITE
Diagnostic sequence – Stage 8
If the restart is successful the 20M LED goes off, the 60 minute timer LED (60M) comes on. The 60M LED remains on
for 60 minutes from restart. A lighted 60M LED indicates that the icemaker has experienced an over-torque condition.
If the icemaker runs without problems for 60 minutes and no additional torque errors occur, the 60M LED goes off and
the icemaker continues normal operation.
INPUT
POWER
G
B
W
COMPRESSOR
C
T.O.L.
RED
WHITE
WHITE
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
ORANGE
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
GEARMOTOR
4
2
BLACK
YELLOW
3
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
1
ORANGE
L
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
GEARMOTOR
4
2
BLACK
YELLOW
3
WATER
SENSOR
WHITE
WHITE
RED
BLACK
1
L
BLACK
BLACK
START
RUN
T.O.L.
WATER
SENSOR
GRD
L1
L1
WHITE
L2
L2
L2
WHITE
L2
L2
RED
COMPRESSOR
BLACK
FAN
DRIVE
BLACK
BLACK
START
RUN
T.O.L.
PWR
RESET
GRD
DR
L1
L1
C
L2
20M
CONTROL
L2
BOARD
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
PWR
RESET
DR
C
20M
CONTROL
BOARD
60M
2ND
WTR
B-T
B-E
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
RED
RED
RED
RED