Specifications

Electrical

Separate circuit and equipment ground required.

Evaporator unit

Standard electrical: 115/60/1
Maximum fuse: 15A
Amperage: 5A
Follett condensing unit – F1412CU
1412 3-Phase (Emerson/Copeland)

Evaporator plumbing

§ 3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required.
§ Water shut-off recommended within 10 feet (3 m).
§ Follett recommends installation of Follett water filter system (part# 00130286) in ice machine inlet water line.

Flush drain plumbing

§ 3/4" MPT flush drain connection at the rear of the machine.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1 inch.
§ Drain should be piped without a vent.
2 ft. x 1" OD
silicone tubing
(6,4 mm per 0,3 m)
HCF1412R, HCF1412K
Electrical
208-230 V, 60 Hz
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1/4" per foot
1'
Min Circuit
Ampacity
12A
1" PVC Drain
Max Circuit HVACR
breaker size
20A
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain