Specifications; Electrical; Evaporator Unit; Condensing Unit - Follett Horizon Elite HC-1810R/N Operation And Service Manual

Hide thumbs Also See for Horizon Elite HC-1810R/N:
Table of Contents

Advertisement

Specifications

Electrical

Separate, dedicated circuit and equipment ground required.

Evaporator unit

Standard electrical: 115/60/1
Maximum fuse: 15A
Amperage: 5A

Condensing unit

Electrical
Max Circuit HVACR breaker size
Min Circuit Ampacity

Evaporator plumbing

§ 3/8" OD push-in water inlet - 3/8" OD tubing required.
§ Water shut-off recommended within 10 feet (3 m).
§ Follett recommends installation of Follett water filter system (part# 00130286) in ice machine inlet water
line.

Flush drain plumbing

§ 3/4" MPT flush drain connection at the rear of the machine.
§ Drain must slope 1/4" per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1".
§ Drain should be piped without a vent.
2 ft. x 1" OD
silicone tubing
(6,4 mm per 0,3 m)
HC_1810R/N, HC_2110R/N, HM_1810R/N, HM_2110R/N
1810 Single-Phase
45A
26.2A
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1/4" per foot
1'
1810 3-Phase
2110 Single-Phase
208-230V, 60Hz
25A
15.7A
1" PVC Drain
2110 3-Phase
45A
27.1A
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain
30A
19.9A
5