Connect the alarm sounding devices (self-contained sirens, speakers or a mechanical bells) to
terminals 5 (+) and 14 (-). Any self-contained siren requiring a 12 VDC input can be connected.
When connecting a mechanical bell, it must be supervised using a 2.2k Ohm resistor. To
connect 8 Ohm Speakers use a Siren Driver with the proper polarity observed. NOTE: Refer to
the Wiring Diagram for alarm current specification, bell supervision and burglary output relay.
Auxiliary Output can be activated depending on the programming options selected (see
GEM-P3200 Programming Instructions). Connect the device controlled by the programmable
output between terminal 8 (+) and terminal 14 (-). A programming option "Aux. Output Chirp on
Key-fob Arming" is available. If selected, an external siren driver can be connected to these
terminals.
NAPCO Security Systems
Connect a 16.5 VAC Transformer to Terminals 1 and 2, using a wire of #18 AWG. or
1
less at a distance of 15 ft. or less from the control panel. NOTE: Do not connect to a
switched outlet.
2
The RED (+) and BLACK (-) flying leads must be connected to
a 12VDC 4, 6 or 7 AH Rechargeable Battery, to serve as
backup power in the event of AC Power Failure. NOTE: To
calculate the available standby time refer to the Standby-
Battery Calculation Worksheet at the back of this manual.