Global System Troubles by Output
System troubles (Low Battery, AC Failure, etc.) can trip any output (Pulsed Burg, Auxiliary, etc.). Note: RF TROUBLE will report
for RF Low Battery, RF Supervisory Failure or GEM-DT Self-Test Failure.
Include Selective/Group Bypass In Conditional Closing/Status See Closing Report
Interior Zones by Area
Interior Normally Bypassed
Auto Interior Bypass
Interior zones that are bypassed (will not trip into alarm) from the system will permit freedom of movement throughout the
premises but still afford protection from intrusion through armed perimeter zones. Pressing the
select the Interior Zones, then arm to bypass. The next time the control panel is disarmed, all bypassed zones will automatically revert
to non-bypassed (disarmed) zones. When the
The bypassed zones may be displayed on the keypad (see GEM-RP1CA/GEM-RP1Ce/RP1CAe2 FUNCTION MODE).
If Interior Normally Bypassed is selected, all Interior Zones will always be inactive. The "    " reminder will always display,
indicating that only partial protection will be provided upon arming. To temporarily restore interior protection, press the
the "    " reminder will go out upon arming, denoting full protection, however Interior Zones will once again be bypassed the next
time the panel is disarmed.
If Auto Interior Bypass is programmed, all Interior Zones will automatically provide protection if the Exit/Entry doors are opened
during exit delay. (Note: Interior Normally Bypassed must be programmed.) If the
restart and Exit/Entry doors may be opened to permit someone to exit (while others remain on premises) without causing an alarm.
Jumpers (Refer to Wiring Diagram for UL configuration.)
A: Cut for dry contacts on the Auxiliary Relay.
B: Cut for dry contacts on the Burglary Relay.
C: Cut for dry contacts on the Reset Relay.
D: Cut if using a PS3002 Power-Supply Module.
JP5: Keypad Configuration Jumper (top-right corner, above micro shield) is installed across top and center pins for normal
operation. When configuring GEM-RP1CA keypads, move jumper across center and lower pins.
JP6 & PS: For Residential Fire. See Alarm Outputs.
JP7: 2-Wire Fire jumpers. Select Zones 7 and/or 8 for use as either 2-Wire Fire Zones or Burglary Zones. Note: If customizing a
single-area default program, Zone 8 is configured as a 2-Wire Fire Zone. In a two-area default program, Zones 7 and 8 are confi gured
as 2-Wire Fire Zones common to both areas; be sure to move JP7 Zone-7 jumper to the 2-WF position (see Wiring Diagram).
Keypad Jumpers: GEM-RP1CA/RP1CAe/RP1CAe2 (Refer to label LA1374 on the circuit board fishpaper for jumper locations and a
summary of settings)
JP1: Cut to enable Keypad Tamper.
W1 & W3: Cut both to disable touchpad backlighting.
W2: Cut to disable LCD backlighting.
Keypad Jumpers: GEM-RP2AS/RP2ASe/RP2ASe2 (Refer to label LA1390 on the circuit board fishpaper for jumper locations and a
summary of settings)
See Section 3: Configuring the GEM-RP2AS Keypad for jumper selection.
Key Fob Transmitters
Aux. Output Chirp on Key-Fob Arming
Don't Clear Aux. Relay with Arm/Disarm
Aux. Output Chirp on Key-Fob Arming will cause a 1-second chirp to sound on arming and a 2-second chirp on disarming. Use
the steady output of a siren driver. Do not use a voice siren driver.
Programming a "C as the Key-Fob Aux-1 or Aux-2 option will provide the ability to toggle the Aux. Relay on or off. If there is an
Aux. Relay timeout programmed, it will follow this timeout unless toggled off by the key fob. To provide key-fob-only control, program
no timeout. Program Don't Clear Aux. Relay with Arm/Disarm to prevent a disarm from resetting the Aux. Relay.
Key-fob users can report openings and closings. Key fobs 1–8 report as Users 25–32, respectively.
Keyfob Zone Assignment
Keyfobs can be assigned to zones to allow individual reporting. Each of the 4 keyfob buttons can be assigned to a zone. For
example, On button = point 1; Off button = point 2; A1 = point 3; A2 = point 4. Up to 32 keyfobs can be assigned to the GEM-P3200,
providing multiple wireless panic buttons on a system, each reporting to the Central Station or a pager and/or annunciating on a
keypad the keyfob zone number with description/location. To assign a keyfob to a zone, program the keyfob as you would a
transmitter, entering the keyfob's ID code, check sum and point number at the appropriate zone.
KeyFob or Keypad Garage Door opener control
The Auxiliary Relay can be programmed to activate for a programmable period of time. This allows it to be used for access
functions such as opening and closing a garage door. This is achieved through a new KeyFob option, Access control,
GEM-P3200 Installation Instructions

button is pressed, the "    " reminder will come on.

button prior to arming will

button is pressed while armed, exit delay will
NAPCO Security Systems
WI817B 11/98

button;