Specifications - NAPCO Gemini P1632 Installation Instructions Manual

Control panel/communicator
Table of Contents

Advertisement

Page 6
GEM-P1632
Operating Temperature: 0-49°C (32-120°F)
Input Power: 16.5VAC via CLASS 2 Plug-In 20VA, 40VA or 50VA Transformer
Loop Voltage: 10-13Vdc
Loop Current: 3mA without Zone Doubling, 2.4mA with Zone Doubling using a 2.2K Ohm end-of-line resistor (Model
EOL2.2K); 5mA for 2-wire smoke-detector zones; 1.4 mA using a 3.9K Ohm resistor (Model EOL 3.9K) with Zone
Doubling
Loop Resistance: 300W max.; 50W for 2-wire smoke-detector zones
Alarm Voltage Output: 1
Programmable Negative Outputs: 2
Auxiliary Power Output: 11.7 VDC to 12.5 VDC
Remote Power Output: 12 VDC regulated (for keypads)
Combined Standby Current (Remote Power + Aux. Power + Reset Relay Power): See following charts.
TRANSFORMER
40VA/50VA
TRANSFORMER
40VA/50VA
40VA/50VA *
(1)
NOTE:
Alarm
creased by reduc-
RESIDENTIAL FIRE PROGRAMMING OPTION: Refer to GEM-P1632 Programming Instructions (WI897) for program-
ming information. This option changes the operation of the power supply in alarm conditions to optimize performance. In
installations that do not monitor fire conditions (Residential and Commercial Burglary) U. L. allows the battery to be
depleted in alarm conditions when AC is present. To prevent the regulator and rectifier from exceeding 75% of their rated
temperature the regulator drops to 10V causing the battery to support the entire alarm current.In installations that do
monitor fire conditions (Residential Fire) U.L. does not allow the battery to be depleted in alarm conditions when AC is
present. Therefore when this bit is set the regulator is not dropped to 10V during alarm conditions. When this bit is set the
current specifications for Residential Fire should not be exceeded. If the specifications are exceeded when a 40VA or
50VA transformer is used the regulator may exceed 75% of its rated temperature up to 85% of its rated temperature at
which point the regulator will protect itself by current limiting. This would cause the battery to deplete, but no damage
would occur to the panel. If a 20VA transformer is used and the Residential Fire current specifications are exceeded then
the Transformer VA rating may be exceeded thereby damaging the transformer.
EZM Module:
GEM-EZM816: Input, 50mA
Keypad Current:
GEM-RP1CAe2: 100mA; 35mA if back lighting is disabled (cut W1, W2 & W3)
PGM Output: 5mA, 12V Special Application
Maximum Number of Keypads: 7
Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and EZMs on run
Keypad Dimensions: 4" x 5" x 1" (HWD); 11.1cm x 14.9cm x 2.7cm (HWD)
GEM-P1632 Installation Instructions
RESIDENTIAL BURGLARY & COMMERCIAL BURGLARY
16.5VAC
BATTERY
(12 VDC)
7 AH
20VA *
7 AH
20VA *
7 AH
16.5VAC
BATTERY
(12 VDC)
7 AH
Two 7 AH
20VA *
7 AH
20VA *
Two 7 AH
rent by the same amount.
* Not evaluated by U.L.
STANDBY
ALARM
CURRENT
CURRENT
650 mA
2.0 A
500 mA
2.0 A
500 mA
2.0 A
RESIDENTIAL FIRE
STANDBY
ALARM
CURRENT
CURRENT
120 mA
520 mA
360 mA
280 mA
120 mA
360 mA
360 mA
120 mA
STANDBY
TIME
4 Hours
4 Hours
6 Hours
STANDBY
TIME
(1)
24 Hours
(1)
24 Hours
(1)
24 Hours
(1)
24 Hours
current can be in-
ing standby cur-
NAPCO Security Systems
WI808B 8/98