NAPCO Gemini GEM-P3200 Installation Instructions Manual page 49

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P3200:
Table of Contents

Advertisement

WI817B 11/98
Time Selection
The following times are programmable:
(1)
TIME
RESET OUTPUT
AUXILIARY OUTPUT
AUXILIARY OUTPUT AC-
CESS CONTROL TIME
BURGLARY OUTPUT
PULSE-BURG OUTPUT
FIRE OUTPUT
ABORT DELAY
CHIME TIME
¼ SEC.
AC-FAIL REPORT DELAY
10 MIN.
EXIT DELAY
ENTRY DELAY 1
ENTRY DELAY 2
TELCO LINE-TEST DLY
AUTO ARM REARM DLY
SENSOR-WATCH TIME
DISARMED HOURS
Note: If both programming locations are left blank, refer to the notes in the Time Selection table for feature timeout.
To select a time up to 15 seconds, 15 minutes, 15 hours, or 15 days, program the respective entry into the second box only; do
not program the first box. To select a time greater than 15 seconds, 15 minutes, 15 hours or 15 days, program both boxes as follows:
1. For the feature selected, choose an appropriate time in units shown (all seconds, minutes, hours, or days — not minutes and
seconds, etc.).
2. Divide the time chosen by 16. Enter the quotient in the 1st BOX and the remainder in the 2nd BOX.
3. Check entries by adding the contents of the 2nd BOX to 16 times the contents of the 1st BOX. (Remember that a "zero" entry
represents 10.)
Example. Program Entry Delay 1 for 1 minutes.
1. Entry Delay 1 is in units of seconds, thus delay time is 90 seconds.
2. Divide by 16: 90/16 = 5 (quotient) + 10 (remainder). Enter the quotient in the 1st BOX and the remainder in the 2nd BOX:
3. Check entries (remember, a "0" entry = 10): (16x5) + 10 = 90.
TouchTone Dialing Only
TouchTone Dialing with Rotary Backup
Select TouchTone Dialing Only if the subscriber has TouchTone service. TouchTone dialing is faster than rotary dialing, but not
always as reliable.
For the communicator to use TouchTone on all dial attempts, program TouchTone Dialing Only. To use TouchTone on the first
attempt with subsequent Rotary dial, program TouchTone Dialing with Rotary Backup. TouchTone Dialing Only will override
TouchTone Dialing with Rotary Backup if both are selected. Note that if Backup Reporting is also selected, the communicator will
alternate between TouchTone and rotary dial to reach Telephone 1, then Telephone 2. See Backup Report on Telco 2.
Transmit "402" Closing Code
Program to send a "402" closing code (for Ademco Point ID modem format) in place of a "401" code.
NAPCO Security Systems
UNITS
MAX. PROG. TIME
MIN.
UNTIMED
MIN.
UNTIMED
SEC.
4 MIN, 15 SEC (255 SEC)
MIN.
UNTIMED
MIN.
UNTIMED
MIN.
UNTIMED
SEC.
4 MIN, 15 SEC (255 SEC)
63.25 SEC (255 QTR-SEC)
42 HR, 30 MIN (2550 MIN)
SEC.
4 MIN, 15 SEC (255 SEC)
SEC.
4 MIN, 15 SEC (255 SEC)
SEC.
4 MIN, 15 SEC (255 SEC)
SEC.
4 MIN, 15 SEC (255 SEC)
MIN.
4 HR, 15 MIN (255 MIN)
255 HOURS
Time t:
0
1
2
3
4
Entry:
*
1
2
3
4
1st BOX
5
quotient
(1)
NOTES:
The output used for Burglary must be at least 4 minutes
in Residential UL installations, 15 minutes in Commercial UL instal-
(2)
lations.
If both locations are left blank, this feature will remain
(2)
active until the system is disarmed. When both locations are pro-
grammed "F", maximum time will be 4 hours, 15 minutes (255
(2)
(3)
minutes).
If both locations are left blank, this feature will not
activate (timeout = 0).
60 sec; Maximum Entry Delay = 45 sec.
are left blank, delay will default to 10 sec.
(1)(2)
disarmed hours (accumulated between armed periods).
(1)(2)
(2)
Any timeout up to those shown in the foregoing table
(3)
may be programmed. Note that each of the above times is
programmed in two locations. The first location has an as-
(3)
signed time factor of 16, the second a time factor of 1.
(4)
(4)
(4)
(5)
(6)
5
6
7
8
9
10 11 12 13 14
5
6
7
8
9
0
B
C
*Blank.
2nd BOX
0
remainder ("0" for 10)
(4)
In UL installations: Maximum Exit Delay =
(5)
If programming locations
(6)
1st BOX
2nd BOX
tx16
tx1
15
D
E
F
GEM-P3200 Installation Instructions
Page 49
Time in units of

Advertisement