Bypassing Zones; Alarm Indication - NAPCO Gemini GEM-P3200 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P3200:
Table of Contents

Advertisement

!
Page 24
Keypad Area Change
To arm or disarm the alternate area:
!
1. Press the number button (1-8) representing the alternate area.
!
2. Press the
G
area selected. In effect, you will now be in that area.
!
3. Arm or disarm the area using your code (the code must be valid in that area).
!
4. To return the keypad to its "home" area, press the
Note: If the "home" keypad has been changed to the alternate area and unused for more than 5 minutes, it will revert to
the home area.

BYPASSING ZONES

Security Bypass
Zones programmed for Selective Bypass may be removed from the system prior to arming as follows:
!
1. Enter a code valid for bypass (Authority Level 1 or higher and Bypass option enabled), then press the
button; "BYPASS ENABLED" will display.
B
!
2. Press the
B
Note: When the panel is subsequently disarmed, all bypassed zones revert to unbypassed zones (unless Disable
Auto-Unbypass on Disarming is programmed or Interior Zones are programmed normally bypassed).
Easy Bypass (Do not enable in UL applications.)
Enable this feature by programming Disable Code Required for Easy Bypass. Then, zones programmed for Selective
Bypass may be bypassed quickly and easily as follows. Note: This is not a high-security feature.
!
1. At the "SYSTEM READY" or "ZONE FAULT" display, enter the zone number as a two-digit number (ex., "01", "15",
etc.). Zones cannot be bypassed while the panel is armed.
!
2. Press the
B
be reversed and this feature will still function.)
Note: If Bypass Faulted Zones is programmed, pressing the
zones in trouble (except Fire and PIR Zones) that are also programmed for Selective Bypass.
Bypassing Interior Zones
Interior zones allow perimeter zones to be armed while part or all of the active interior remains disarmed. When the
button is pressed, the "BYPASSED" reminder will come on. Pressing the
E
selected interior group without arming, otherwise Interior Bypass will time out and the system will revert to the regular
disarmed state. All zones designated for the selected interior group(s) will be bypassed simultaneously when the system
is armed. The alarm conditions will then be stored in the Alarm History Log and the Total Event Log (see HISTORY
LOG).

ALARM INDICATION

!
To silence an alarm, enter a valid User Code, then press the
Should a burglary alarm occur, the red ARMED LED will flash, and the display will alternately read "ALARM", then the zones
violated. Disarm the panel; the display will read "ALARM" and will continue to indicate the violated zones until the
button is pressed or the panel is armed once again.
X
GEM-P3200 Installation Instructions
J
button, then the
button. The keypad will display "SYSTEM READY X", where "X" denotes the
button, then the zone number (or vice versa) to deactivate that zone.
button. To unbypass the zone, press the
J
button, then the
G
button again. Note: Steps 1 and 2 may
B
and the
buttons simultaneously will bypass all
G
B
J
button within 10 seconds will bypass the
J
button.
L
WI817C 08/00
button.
C
NAPCO Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents