REMOTE BUS

Connect the available devices as shown above to the remote bus terminals (9, 10, 11 & 12). Observe the correct color
wire connections. When connecting a keypads, first configure them accordingly (refer to the Keypad Configuration Mode
at the back of this manual). Keypads should be located near every exit/entry door. Up to seven keypads may be
connected if the longest cable run from the panel, to the farthest keypad (daisy chained or home-run) is less than 1000
feet. The maximum distance for seven keypads is 300 feet using 22 AWG. wire. NOTE: When running keypad wire, avoid
wiring parallel to other types of wiring that can cause electrical interference.

EARTH GROUND

NOTE: Do not use a gas pipe, plastic
pipe or AC ground connections.

AUXILIARY POWER

Connect the auxiliary devices (motion detectors, glass breaks, etc.) to Terminals 13 and 14.
(+)
13
Auxiliary Power provides a filtered 12 VDC nominal output which is used for powering auxiliary
AUX POWER
devices. NOTE: To calculate the available standby time refer to the Standby-Battery Calculation
(-)
Worksheet at the back of this manual.
14
X
GEM-P3200 Installation Instructions
NOTE: Refer to the EZM Installation Instructions for specific
wiring information.
AVAILABLE DEVICES
1. KEYPADS: GEM-RP1CAe2, GEM-RP2ASe2 & GEM-RP3DGTL
2. X-10 INTERFACE: GEM-X10
3. WIRED ZONE EXPANDER: GEM-EZM4 & GEM-EZM8
4. WIRELESS RECEIVERS: GEM-RECV8, GEM-RECV16 & GEM-RECV96
5. RELAY MODULE: RM3008
6. VOICE INTERFACE: GEM-EVA 1
7. TELEPHONE INTERFACE: WIZARD IIe
GEMINI
SYSTEM ARMED
01/01/97
12:00AM
N EX T/Y ES
A
1 2
3
E
D
P RIOR /NO
B
4
5 6
F
AR E A
C
7 8 9 0
G
C OM PU TERIZED SEC U RITY SYSTEM
R
GEM-RP1CAe2
(2 LINE LCD KEYPAD)
Connect the control panel EARTH GROUND screw through a No. 16 AWG.
or larger wire to a metal cold-water pipe. Do not use a gas pipe, plastic pipe
or AC ground connections. Also, connect the circuit board to the metal
enclosure. Connect a wire with a ground lug crimped or soldered onto one
end of the EARTH GROUND screw to the cabinet. NOTE: Grounding
connections should avoid bends in the grounding wire whenever possible.
WI817C 08/00