NAPCO Gemini GEM-P3200 Installation Instructions Manual page 47

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P3200:
Table of Contents

Advertisement

WI817C 08/00
If reporting openings and/or closings, program Subscriber Opening/Closing Identification Numbers for each area for each
telephone number used. If reporting events, program Subscriber ID Numbers for each area for each telephone number used.
Subscriber ID numbers must be programmed for each area and telephone number, even if all are the same. Start with the left-most
location.
Sum Check See Data Format
Supervised Bell Output
When the option Supervised Bell Output is enabled, a 2.2K ohm resistor must be installed across the bell or sounding device
terminals. In the event that the Burg Output is cut, or the circuit is opened, an E51-00 FIRE BELL TRBL trouble condition will occur.
Note: Due to the fact that there is a constant loop current flowing through the Burg Output circuit for supervision, some sirens or siren
drivers may emit a low volume hum or buzz if the 2.2K EOL resistor is not installed. If Supervised Bell Output is not required, this can
be eliminated by cutting resistor R207 which is located just to the right of the Burg Output relay adjacent to the Burg Output terminal.
Suppress "BYPASSED" Reminder When Armed (Must be enabled in all UL systems)
Program to inhibit the LCD "BYPASSED" display while armed.
Swinger Shutdown (Do not program for UL Installations.)
Program for zones with Auto-Reset to only reset twice (3 alarms) until rearmed to prevent "swingers" (intermittents) from causing
repeated false alarms. See Auto-Reset. The Swinger-Shutdown feature is programmable by zone, but is not applicable to Ambush.
System Troubles (Global and Area)
System troubles may be programmed to report to any telephone number and/or activate any output. Also program Subscriber ID
Numbers, Telephone Numbers, and Report Codes for each system trouble.
Note: RF TROUBLE will report for RF Low Battery, RF Supervisory Failure or GEM-DT Self-Test Failure.
System Trouble Audible Automatic Timeout
Inhibit System Trouble Audible
In the event of a System Trouble while the system is disarmed, the keypad will scroll the trouble description in the display and
activate the sounder until [RESET] is pressed. If [RESET] has not been pressed within 10 minutes of the trouble, the sounder will
automatically turn off in 10 minutes.
To disable System Trouble Audible Automatic Timeout , enable Disable System Trouble Audible Timeout in the PCD3000
Keypad Features screen. NOTE: If the system were Armed when the trouble occurred, the keypad would display the SYS TBL icon,
but NOT activate the sounder.
For installations where an audible on system trouble is not desired at all, the option, Inhibit System Trouble Audible can be
enabled. Regardless of the system status, Armed or Disarmed, there will be no keypad sounder at all in the event of a system
trouble. However, the trouble will still scroll in the keypad display until [RESET] is pressed and the SYS TBL
the trouble is restored. (Do Not program in UL Installations)
To disable System Trouble Audible, enable the option disable System Trouble Audible in the PCD3000 Keypad Features
screen.
Tamper
EZM Tamper
Keypad Tamper
RF Tamper
Removing the cover of an expansion zone module will cause the sounder to pulse and the "SYS/TRBL" reminder to flash. The
keypad will display "E13-NN BURG EZM TAMPER", where "NN" denotes the module number. Press the
("SYSTEM READY" will display). Correct the problem, then select RESET SYSTEM TBL to manually reset the system trouble display.
Removing a keypad from the wall causes a similar system trouble indication. The keypad will display "E11-NN BURG KPD TAMPER",
where "NN" denotes the keypad number. Press the
reset the system trouble, correct the problem then select RESET SYSTEM TBL.
Note: If either of the tamper conditions is not corrected within 5 minutes, the system trouble will again display at the keypad.
A Tamper condition can be programmed to activate the burglary output and/or report using its associated system Report Code.
In wireless installations, when displaying RF transmitter status, a "Tamper" indication denotes that the transmitter case is open.
Telco Answering Service Override
If using the PCD3000 PC downloader Software, the Telco Answering Service can now be disabled. Call the panel, hang up after
one ring by pressing the F10 key. The PCD3000 will automatically call the panel back and the panel will answer in one ring.
Telco Fail See Enable Line-Fault Test
TELCO FAIL ONLY WHEN ARMED
The Telco Line Cut Monitor will only be active when the system is armed.
Telco Line Test Delay See Enable Line-Fault Test; Time Selection
Telemetry Trouble
L
NAPCO Security Systems
C
button to silence the sounder ("SYSTEM READY" will display). To manually
X
icon will display until
button to silence the sounder
C
GEM-P3200 Installation Instructions
!
Page 47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents