■ Production control input screen
6
3)­ Set­the­respective­setting­items­with­ 7 .­Setting­time­inputted­in­ 6 ­is­shown­in­reverse­video.
Minimum setting possible value of pitch time is 0.50 seconds.
When 0.00 second is set, make the current target non-display.
4)­ Press­ 8 ­in­the­shape­list­screen.
■ Output display screen
5)­ The­output­display­screen­is­displayed.­Sewing­is­possible­with­this­screen.
­ Set­value­can­be­changed­with­switches­ 9 ­and­!0 (Editing of the final target value and pitch time cannot
be­performed­in­this­screen.)
­ The­current­target­value­and­the­current­output­can­be­cleared­(make­them­"0")­with­switch­!1 .
­ Setting­of­start/stop­of­the­output­display­function­can­be­performed­with­switch­!2 .
7
7
8
9
!1
!0
!2