Operating Instructions; Lighting Procedure; Shutdown Procedure; First Fire - Regency ULTRAGLOOW G36D-LP Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the ap-
pliance with the glass removed.
5) Verify that the venting and cap are unob-
structed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot,
you must fi rst release the ten-
sion springs below the door.
Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not be operated with the tension springs
unattached.
IMPORTANT Gas cock knob cannot be turned
from "PILOT" to "OFF" unless it is partially
depressed.
1) Turn burner OFF using "ON/OFF" switch.
32
2) Turn gas control knob so indicator points
to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.
3) Turn gas control knob counterclockwise
so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button several times until the
pilot lights. After approximately one minute,
release the gas control knob. The pilot fl ame
should continue to burn. If the pilot does
not remain lit, repeat operation allowing a
longer period before releasing gas control
knob.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON" posi-
tion.
5) Use the wall switch, thermostat or remote
control to turn on the unit.
6) Rotate the fl ame height regulator to adjust
the fl ame height higher or lower.
SHUTDOWN
PROCEDURE
1) Use the wall switch, thermostat or remote
control to turn off the main burner.
2) Turn the main gas control clockwise to the
"OFF" position to turn off the pilot.
3) Turn off all electric power to appliance if
service is to be performed.

FIRST FIRE

The fi rst fi re in your stove is part of the paint cur-
ing process. To ensure that the paint is properly
cured, it is recommended that you burn your
fi replace for at least four (4) hours the fi rst time
before you use it with the fan on.
When fi rst operated, the unit will release an
odour caused by the curing of the paint, the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go
off at this time. Open a few windows to ventilate
the room for a couple of hours.
The glass panel may require cleaning after the
DO NOT ATTEMPT
unit has cooled down.
TO CLEAN THE GLASS WHILE IT
IS HOT.
Note: When the glass is cold and the appli-
ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
AERATION
ADJUSTMENT
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the
air shutter for a blue fl ame or close for a yel-
lower fl ame. The burner aeration is factory set
but may need adjusting due to either the local
gas supply or altitude.
Minimum Air Shutter Opening:
3/16"
1/2"
CAUTION: Carbon will be produced if air shutter
is closed too much.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Note: Aeration Adjustment should only be
performed by an authorized Regency
Installer at the time of installation or
service.
Adjustment Wire: push to close or
pull to open aeration cap.
Closed - Tall yellow
Open - Short Blue
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace
Natural Gas
Propane