Venting; Direct Vent System (Flex) - Regency ULTRAGLOOW G36D-LP Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION

VENTING

UltraGlow Direct Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 10.
UltraGlow Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the G36D with a maximum
total run of 4 feet.
1) 6-7/8" dia. fl exible liner (4 ft. length)
2) 4" dia. fl exible liner (4 ft. length)
3) spring spacers (4)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace
11