Vertical Terminations - Co-Linear Flex System - Regency ULTRAGLOOW G36D-LP Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the Venting
Arrangements on next page for minimum and
maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter
Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Rigid Pipe Adaptor
Alternate Approved Caps
980
Vertical Termination Cap
991
High Wind Cap
923GK 3" Co-linear Adapter with fl ashing
FPI Cabinet and/or Flat Wall Mantles
may be used in these applications en-
suring that clearances to combustibles
are maintained.
18
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
#948-305 (35 ft)
Outer
Pipe
with Kit#
946-563
Pipe Length
Rigid Pipe Adaptor
# 510-994
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
of two certified
joiner kits
may be used
per length.
Exhaust
Flue
90 Degree
Elbow
Inner Pipe
Adapter
with Kit#
946-563
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace
Flex Liner
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563