B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause fire.
Mantels (Combustible/Non-Combustible)
1,3 cm
Thick Wall
Sheathing
36 cm
Figure 13.5 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Note: For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 13.C.
Mantel Leg (Combustible/Non-Combustible)
TOP VIEW
8 cm
MINIMUM
18 cm
Figure 13.6 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
C. Facing Material
• Facing and/or finishing materials must not interfere with
air flow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or finishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
30 cm
MAX.
MEASUREMENT
FROM TOP OF
FIREPLACE
MIN.
OPENING
UNLIMITED
Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
WARNING! Risk of Fire! DO NOT install drywall or other
combustible materials over the factory-installed non-com-
bustible board. Overlapping materials could ignite.
Decorative facing material thickness is measured from
the face of the factory-installed non-combustible board.
See Figure 13.7
3,8 cm ABOVE STANDOFF
DRYWALL OR
EQUIVALENT (1,2 cm)
Figure 13.7 Overlap Fit Method (Tonic or Martini Decorative
Front)
Both the Tonic and Martini decorative fronts can be in-
stalled with an "Overlap" or "Inside Fit" method:
Overlap Requirement: See Figure 13.7.
Inside Fit requirement: See Figure 13.8 and 13.9.
Non-Combustible Finish Materials
0 - 2,54 cm Thickness-Overlap Fit Method
Both the Tonic and Martini decorative fronts are designed
to overlap finish materials 0 cm to 2,54 cm thick. See
Figure 13.6.
NOTICE: This 2.54 cm maximum not only includes the
decorative finish materials (marble, tile, slate, etc) but
also the mortar or adhesive used to attach the decorative
finish material.
The non-combustible finish material can be installed up to
the fireplace opening.
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE
FINISHING MATERIAL
0 - 2,5 cm THICK
TONIC DECORATIVE
FRONT SHOWN
NON-COMBUSTIBLE
FINISHING MATERIAL
0 - 2,5 cm THICK
47