READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 2005
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195,
6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426,
6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia)
780250, 780403, 1418504 or other U.S. and foreign patents pending.
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05
Owner's Manual
Installation and Operation
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed
plumber or gas fitter;
• a CO detector shall be installed in the room
where the appliance is installed.
Please contact your Heat & Glo dealer with any
questions or concerns. For the number of your nearest
Heat & Glo dealer, please call 1-888-427-3973.
Underwriters
Laboratories Listed
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000TV-OAK

  • Page 1 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 2: Safety And Warning Information

    DO NOT place furniture or any other combustible Young children should be CAREFULLY SUPERVISED household objects within 36 inches of the fireplace when they are in the same room as the appliance. front. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 3: Table Of Contents

    Step 12 Before Lighting the Fireplace ........19 Step 13 Lighting the Fireplace ..........19 After the Installation ..............19 Section 4: Maintaining and Servicing Your Fireplace..20 = Contains updated information. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 4: Service Parts Lists

    Service Parts 6000TV-OAK, 6000TV-OAK-IPI (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ 6 Log Set Assembly Part number list on following page. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 5 383-250A Junction Box POST 002324021 4021-013 Conversion Kit LP LPK-6TVOC-IPI ACCESSORIES Trim Door Mesh MESH-6000 Fan Kit GFK-160A Wall Switch Kit, Off-white WSK-21 Wall Switch Kit, White WSK-21-W Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 6: Service Parts

    POST 002324021 Pilot Bracket 385-164 002324021 550-169 Valve Bracket POST 002324021 2025-101 Ground Strap 2025-512 3V Adaptor Plug 593-593A Battery Pack 593-594A 72" & 80" Wire Assembly 522-504A Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 7 Burner Orifice (NG) (#40C) 582-840 Burner Orifice (LP) (#53C) 582-853 002324021 550-169 Valve Bracket POST 002324021 2025-101 Flex Ball Valve Assembly 302-320A Piezo Ignitor 291-513 80" Wire Assembly 522-503A Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 8: Section 1: Approvals And Codes

    (in the United States) which has a total volume of unconfined space appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA54 Heat & Glo Quality Systems registered by SGS ICS Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 9: Section 2: Getting Started

    Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 10 (55mm) 36-1/8 (916mm) 6-7/8 6-1/2 (174mm) (1043mm) (165mm) VENT COLLARS STANDOFFS HOOD RATING PLATES & LABELS OUTSIDE CONTROLS GAS ACCESS ELECTRICAL ACCESS Figure 1. Diagram of the 6000TV-OAK Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 11: Section 3: Installing The Fireplace

    (546 mm) into combustible construction. pipe. The minimum clearance from the top face of the fireplace to combustible finishing materials such as drywall, is one inch (25mm). Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 12: Step 2 Framing The Fireplace

    Figure 4. Make-up Air pressure within the structure where the fireplace is located. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 13: Step 4 Installing The Vent System

    Consult Local Building Code Officials and Codes for proper vent system installations. WARNING: THIS GAS FIREPLACE MUST NEV- ER BE VENTED BY CONNECTING TO A CHIM- NEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 14: Bedroom Installation In Canada

    The IPI system includes a 3V control valve, electronic mod- ule, and intermittent pilot. WARNING: CONTINUOUS 110-120 VAC SER- VICE MUST BE WIRED TO THE FIREPLACE JUNCTION BOX. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 15: Step 7 The Gas Supply Line

    (1/2) psig (3.5 kPa). Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 16: Step 9 Wiring The Fireplace

    REPLACED WITH TYPE 105 C RATED WIRE. JUNCTION BOX BLOWER RECEPTACLE GROUND TEMPERATURE SENSOR SWITCH BLOWER 110-120 VAC SENSOR BLOWER SWITCH “FAN” RECEPTACLE SPEED CONTROL Figure 11. Fan Wiring Diagram Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 17 3 volts. 120 VAC BROWN is required at junction box unless TEMP SENSOR equipped with battery back-up. VALVE Figure 12. Intermittent Ignition (IPI) Wiring Diagram Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 18: Step 10 Finishing

    However, ANSI or CAN/CGA testing standards do not require • Pull out and latch the glass clips into the groove on the glass frame. hearth extensions for gas fireplace appliances. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 19: Glass Specifications

    MANUAL FOR ALL CAUTIONS, SAFETY, AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF THE FIREPLACE. After the Installation LEAVE THIS INSTALLATION MANUAL WITH THE APPLIANCE FOR FUTURE REFERENCE. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...
  • Page 20: Section 4: Maintaining And Servicing Your Fireplace

    (standing pilot) tips should be covered with or attempt to clean the door when it is hot and DO NOT flame. See Figure 8. use abrasive cleaners. Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05...