2Nd Motor Selection - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

nd
2
Motor Selection
This function allows you to switch the inverter setting to control two different types of
motors. To use this function, assign function "08" to one of the input terminal and make
it on or off. When 2
No.
Codes
1
Acceleration time (1)
F202
2
Deceleration time (1)
F203
3
Frequency source
A201
4
Run command source
A202
5
Base frequency
A203
6
Maximum frequency
A204
7
Multi-speed frequency 0
A220
8
Torque boost select
A241
9
Manual torque boost value
A242
10
Manual torque boost freq.
A243
11
V/f characteristic curve
A244
12
V/f gain
A245
13
Voltage comp. gain for automatic torque boost
A246
14
Slip comp. gain for automatic torque boost
A247
15
Frequency upper limit
A261
16
Frequency lower limit
A262
17
AVR function select
A281
18
AVR voltage select
A282
19
Acceleration time (2)
A292
20
Deceleration time (2)
A293
21
Select method to switch to Acc2/Dec2 profile
A294
Option
Terminal
Code
Symbol
60
SETM
2
11, 12, AL0 – AL2
Valid for inputs:
Required settings
Notes:
motor parameters are selected, output signal SETM turns on.
nd
Description
Function Name
nd
motor selection
No.
Codes
22
Acc1 to Acc2 frequency transition point
A295
23
Dec1 to Dec2 frequency transition point
A296
24
Overload warning level
C241
25
Motor data selection
H202
26
Motor capacity
H203
27
Motor poles
H204
28
Motor speed response
H205
29
Motor stabilization constant
H206
30
Motor constant R1 (Hitachi motor)
H220
31
Motor constant R2 (Hitachi motor)
H221
32
Motor constant L (Hitachi motor)
H222
33
Motor constant I0 (Hitachi motor)
H223
34
Motor constant J (Hitachi motor)
H224
35
Motor constant R1 (Auto tuned data)
H230
36
Motor constant R2 (Hitachi motor)
H231
37
Motor constant L (Hitachi motor)
H232
38
Motor constant I0 (Hitachi motor)
H233
39
Motor constant J (Hitachi motor)
H234
State
nd
ON
2
motor parameter sets are selected
st
OFF
1
motor parameter sets are selected
Example for terminal [11] (default output
configuration shown – see
Inverter output
terminal circuit
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
Inverter logic
circuit board
AL0
Power
supply
See I/O specs on
Description
Description
page
3-90):
SETM
CM2
11
RY
page 4-52 and
3-90):
SETM
AL1
AL2
Load
page 4-6
4−85

Advertisement

Table of Contents
loading

Table of Contents