Func.
Name
Code
Controlled deceleration on
B050
power loss
DC bus voltage trigger level
B051
of ctrl. decel.
Over-voltage threshold of
B052
ctrl. decel.
Deceleration time of ctrl.
B053
decel.
Initial freq. drop of ctrl.
B054
decel.
Maximum-limit level of
B060
window comparator (O)
Minimum-limit level of
B061
window comparator (O)
Hysteresis width of window
B062
comparator (O)
Maximum-limit level of
B063
window comparator (OI)
Minimum-limit level of
B064
window comparator (OI)
Hysteresis width of window
b065
comparator (OI)
Operation level at O
b070
disconnection
Operation level at OI
b071
disconnection
Ambient temperature setting
b075
Watt-hour clearance
B078
Watt-hour display gain
b079
Start frequency
B082
Carrier frequency
B083
"b" Function
Description
Four option codes:
00...Trips
01...Decelerates to a stop
02...Decelerates to a stop with DC
bus voltage controlled
03...Decelerates to a stop with DC
bus voltage controlled, then
restart
Setting of DC bus voltage to start
controlled decel. operation. Range
is 0.0 to 1000.0
Setting the OV-LAD stop level of
controlled decel. operation. Range
is 0.0 to 1000.0
Range is 0.01 to 3600.0
Setting of initial freq. drop.
Range is 0.0 to 10.0 Hz
Set range, {Min.-limit level (b061)
+ hysteresis width (b062)x2} to
100 %
(Minimum of 0%)
Set range, 0 to {Max.-limit level
(b060) - hysteresis width
(b062)x2} % (Maximum of 0%)
Set range, 0 to {Max.-limit level
(b060) - Min.-limit level (b061)}/2 %
(Maximum of 10%)
Set range, {Min.-limit level (b064 +
hysteresis width (b065)x2} to
100 %
(Minimum of 0%)
Set range, 0 to {Max.-limit level
(b063) - hysteresis width
(b065)x2} % (Maximum of 0%)
Set range, 0 to {Max.-limit level
(b063) - Min.-limit level (b064)}/2 %
(Maximum of 10%)
Set range, 0 to 100%, or "no"
(ignore)
Set range, 0 to 100%, or "no"
(ignore)
Set range is,
-10~50 °C
Two option codes:
00...OFF
01...ON (press STR then clear)
Set range is,
1.~1000.
Sets the starting frequency for the
inverter output, range is 0.10 to
9.99 Hz
Sets the PWM carrier (internal
switching frequency), range is 2.0
to 15.0 kHz
C−15
Run
Defaults
Mode
Lnitial data
Units
Edit
00
220.0/
V
440.0
360.0/
V
720.0
1.0
sec
0.0
Hz
100.
%
0.
%
0.
%
100.
%
0.
%
0.
%
no
-
no
-
40
°C
00
-
1.
0.50
Hz
2.0
kHz