Loopback Test [08H] - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

B−14

Loopback Test [08h]:

This function checks a master-slave transmission using any test data. An example
follows:
• Send test data to an inverter having slave address "1" and receiving the test data
from the inverter (as a loopback test).
Query:
No.
1
Slave address *1
2
Function code
3
Test subcode
(high order)
4
Test subcode
(low order)
5
Data (high order)
6
Data (low order)
7
CRC-16 (high order)
8
CRC-16 (low order)
Note 1:
When test subcode is for echo (00h, 00h) only and not available to the other commands.
Example
Field Name
Broadcasting is disabled.
Response:
No.
(Hex)
01
1
Slave address *1
08
2
Function code
00
3
Test subcode
(high order)
00
4
Test subcode
(low order)
Any
5
Data (high order)
Any
6
Data (low order)
CRC
7
CRC-16 (high order)
CRC
8
CRC-16 (low order)
Example
Field Name
(Hex)
01
08
00
00
Any
Any
CRC
CRC

Advertisement