Install Gas Supply; Gas Line Piping; Test Connections; Check That All Burner Valves Are Off - Weber SUMMIT SILVER B Owner's Manual

Natural gas grill
Hide thumbs Also See for SUMMIT SILVER B:
Table of Contents

Advertisement

are genera requirements ta
ANISI Z223. ! lates t edition for complete specifications,
This barbecue is designed to operate at7 inches of'
more than 0.3 grams of hydrogen sulfide per 100 cubic
water column pressure (!2526 psi)i
feet of gas,
• A manual shut-off valve must be installed outdo0rsl
Plastic tubing is suitable only for outdoor, undergrouna
immediately ahead of the quick disconnect.
An additional manual shut-off valve indoors should be
installed in the branch fuel line in an accessible location
near the supply line
The quick disconnect connects to a 3/8 inch NPT
thread from the gas source. The quick disconnect fitting
is a hand-operated device that automatically shuts OFF
the flow of gas from the source when the barbecue is
disconnected
The quick disconnect fitting can be installed
horizontally, or pointing downward. Installing the fitting
with the open end pointing upward can result in
collecting water and debris.
The dust covers (supplied plastic plugs) help keep the
open ends of the quick disconnect fitting clean while
disconnected.
Pipe compound should be used which is resistant to the
action of natural gas when connections are made.
The outdoor connector must be firmly attached to rigid,
permanent construction.
A_ WARNING: Do not route the 12 foot hose under a
deck, The hose must be visible,
Inside wall
-"_ Outside
wall
This is a typical installation
of a Weber® natural gas
barbecue. Local codes may
require different
installations.
Quick
3/8"
Pipe
disconnect
nipple
C405_NG,c
o
Not Use
Gas supply
use.
Gas piping in contact with earth, or any other material
which may corrode the piping, must be protected
against corrosion in an approved manner.
Underground piping must have a minimum of 18" cover
Test Connections
All connections and joints must be thoroughly tested for
leaks in accordance with local codes and all listed
procedures in the latest edition of ANSI Z223.1
z_ DANGER
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for gas
leaks. This will result in a fire or explosion
which can cause serious bodily injury or
death and damage to property.
Check that all burner valves are off
Valves are shipped in the OFF position, but you should
check to be sure that they are turned OFR Check by
pushing down and turning clockwise. If they do not turn,
they are off. Proceed to the next step. If they do turn
continue turning them clockwise until they stop, then they
are off. Proceed to the next step.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Summit gold b43721

Table of Contents