EverFocus ERS-4 Instruction Manual page 36

4 channel video server/ recorder
Hide thumbs Also See for ERS-4:
Table of Contents

Advertisement

Edit Motion Grid
Alarm Output
Output Type
Timeout Duration
Apply To
Save Ch 1...4
Select the detection area in this submenu:
Sensitivity:
Set the threshold value for sensitivity. Select from 1 (lowest) to 10
(highest).
Min Area:
To avoid false detections by small objects this value defines, how
many grids have to be detected for generating a motion event.
Select a value between 1 (default) to 5 grids.
Set All:
Clear All:
Press this button to clear all the grids selected.
For defining a customized detection area click on "CLEAR ALL", the draw by mouse
(hold left mouse key) an area.
Close:
Save setting and return to MOTION menu
In case of event the output relay will switch. It can be set to either "NONE" (not
active) or "1" (relay activated) .
Output action when motion is triggered.
Alarm output lasts for the set time duration.
Transparent:
Timeout:
Transparent+Timeout: Alarm will reset after event ended + Timeout Duration.
This button can be used to copy the image settings to other cameras. Select which
camera you wish to copy to.
"Select All" selects all cameras, "Unselect All" deselects all cameras. Click "OK" to
copy the settings or "Cancel" to exit without copying.
Clicking on this button will save the changed settings for this camera.
Press this button to select the entire area.
Alarm is active as long the event is active.
Automatic alarm reset after a defined time (Timeout
Duration)