G0514X3 440v
conversion
the Model g0514X3 can be converted for 440v
operation. this conversion job consists of discon-
necting the saw from the power source, changing
the connections on the magnetic switch and rewir-
ing the motor for 440v operation.
the Model g0514X3 440v Conversion Kit (part
#p0514X3161av2) for this procedure can be pur-
chased by calling grizzly Customer service at
(800) 523-4777.
all wiring changes must be performed by an elec-
trician or qualified service personnel before the
bandsaw is connected to the power source. if, at
any time during this procedure you need help, call
grizzly tech support at (570) 546-9663.
To rewire the Model G0514X3 for 440v opera-
tion:
1.
disConneCt BandsaW FroM poWer!
2.
remove the magnetic switch cover, then
disconnect and remove the 220v magnetic
switch (figure 9).
figure 9. 220v magnetic switch
G0514X/-X2/-X2B/-X3 (Mfg. Since 2/12)
3.
install the 440v magnetic switch and wire it
according to the G0514X3 Wiring Diagram
on page 72.
4.
remove the motor junction box cover, rewire
the motor as shown on the diagram located
inside the junction box, then re-install the
cover.
Note: The reference motor wiring diagram on
Page 72 was current at the time of printing,
but always use the wiring diagram provided
inside the motor junction box, as it will reflect
any changes to the motor shipped with your
machine.