Problem
Possible cause
Total pixels setting
Active pixels setting
cannot be increased.
may be too low.
Horizontal start
may be too high.
Output resolution may Press the front panel Output Rate
be too low.
Active lines setting
Vertical start
cannot be increased.
may be too high.
Output resolution may Press the front panel Output Rate
be too low.
Horizontal start
Total pixels setting
setting cannot be
may be too low.
increased.
Active pixels setting
may be too high.
Active lines setting
Vertical start.
may be too high.
IN1508 Scaling Presentation Switcher • Operation
Solution
Select Picture>Advanced>Active
Pixels and increase the setting to
match the input signal.
Select Picture>Advanced>H
Start and reduce the setting to
match the input signal.
button to select a setting that is
greater than or equal to the active
area.
Select Picture>Advanced>
V Start and reduce the setting to
match the input signal.
button to select a setting that is
greater than or equal to the active
area.
Select Picture>Advanced>Total
Pixels and increase the setting to
match the input signal.
Select Picture>Advanced>Active
Pixels and reduce the setting to
match the input signal.
Select Picture>Advanced>Active
Lines and reduce the setting to
match the input signal.
3-43