installation
spacing
for cabinet
installation
The dimensions
shown
are for the recommended
spacing.
For cabinet
installation,
with
a dooi; the minimum
ventilation
openings
in the top are
7"(178 ram)
7"(178 ram}
required.
DD
4"
311/2 ''
1"
(102 ram}
(SOOram} (25 ram} (25 ram} (886 ram}
(25 ram}
1"
1"
27"
The washer
can be installed
using the standpipe
drain system (floor or wall),
the laundry
tub
drain
system, or the floor drain
system. Select the drain
hose installation
method
you need.
See "Tools and Parts."
Standpipe
drain
system
- wall
or floor
(views
A & B)
The standpipe
drain
requires
a minimum
diameter
standpipe
of 2" (50 mm). The minimum
carry-away
capacity
can be no less than
17 gal. (64 I_) per minute.
The top of the standpipe
must be at least 30" (762 mm) high and no higher
than 96" (2.4 m)
from the bottom
of the washer.
A
T
39"rnin.
(762 ira}
B
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. 176 I.) capacity. The top of the laundry tub must
be at least 30" (762 mm) above the floor.
Floor
drain
system
(view
D)
The floor drain
system requires
a siphon
break that may be purchased
separately.
See "Tools
and Parts."
The siphon
break must be a minimum
of 28" (711 mm) from the bottom
of the washer.
Additional
hoses might be needed.
iii7
D
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
A 120 volt, 60 Hz., AC only, 15- or 20-amp,
fused electrical
supply
is required.
Time-
delay fuse or circuit
breaker
is recommended.
It is recommended
that a separate
circuit
serving only this washer
be provided.
8