Nortel 1000 Installation And Commissioning Manual page 34

Isdn basic rate interface installation and commissioning
Table of Contents

Advertisement

34 Installing ISDN BRI hardware
Port signals
SILC
2Tx - / 2Tx +
2T / 2R
2Rx + / 2Rx -
3Tx - / 3Tx +
3T / 3R
3Rx + / 3Rx -
4Tx - / 4Tx +
4T / 4R
4Rx + / 4Rx -
5Tx - / 5Tx +
5T / 5R
5Rx + / 5Rx -
6Tx - / 6Tx +
6T / 6R
6Rx + / 6Rx -
7Tx - / 7Tx +
7T / 7R
7Rx + / 7Rx -
0Tx - / 0Tx +
0T / 0R
0Rx + / 0Rx -
1Tx - / 1Tx +
1T/ 1R
1Rx + / 1Rx -
2Tx - / 2Tx +
2T / 2R
2Rx + / 2Rx -
3Tx - / 3Tx +
3T / 3R
3Rx + / 3Rx -
Table 7 "NT8D37 IPE moduleSILC and UILC pair-terminations for
connectors C, G, M, T (12-cable configuration)" (page 34)
pair-terminations for connectors C, G, M, T.
Table 7
NT8D37 IPE module
SILC and UILC pair-terminations for connectors C, G, M, T (12-cable configuration)
Port signals
SILC
4Tx - / 4Tx +
4T / 4R
4Rx + / 4Rx -
5Tx - / 5Tx +
5T / 5R
5Rx + / 5Rx -
6Tx - / 6Tx +
6T / 6R
6Rx + / 6Rx -
Copyright © 2003-2007, Nortel Networks
.
UILC
Pairs
30 / 5
W-S / S-W
31 / 6
R-BL / BL-R
32 / 7
R-O / O-R
33 / 8
R-G / G-R
34 / 9
R-BR / BR-R
35 / 10
R-S / S-R
36 / 11
BK-BL / BL-BK
37 / 12
BK-O / O-BK
38 / 13
BK-G / G-BK
39 / 14
BK-BR / BK-BR
40 / 15
BK-S / S-BK
41 / 16
Y-BL / BL-Y
42 / 17
Y-O / O-Y
43 / 18
Y-G / G-Y
44 / 19
Y-BR / BR-Y
45 / 20
Y-S / S-Y
46 / 21
V-BL / BL-V
47 / 22
V-O / V-O
48 / 23
V-G / G-V
49 / 24
V-BR / BR-V
UILC
Pairs
26 / 1
W-BL / BL-W
27 / 2
W-O / O-W
28 / 3
W-G / G-W
29 / 4
W-BR / BR-W
30 / 5
W-S / S-W
31 / 6
R-BL / BL-R
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard
Release 5.0 20 June 2007
I/O panel connectors
B
Pair color
s
lot
2
I/O panel connectors
Pair color
C
s
lot
2
Card
F
L
S
port
2
3
4
5
6
7
slo
s
s
0
t 6
lot
lot
10
14
1
2
3
shows
Card
G
M
T
port
s
s
4
slot
lot
10
lot
6
14
5
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000Cs 1000