Procedure 24 Initializing A Nortel Networks M5317Tdx Terminal - Nortel 1000 Installation And Commissioning Manual

Isdn basic rate interface installation and commissioning
Table of Contents

Advertisement

80 Configuring ISDN BRI hardware
Procedure 24
Initializing a Nortel Networks M5317TDX terminal
Step
The following is an example of the steps to initialize an M5317TDX terminal.
Table 19 "M5317TDX terminal error codes" (page 81)
error codes that can appear during terminal initialization. Additional
information is contained in the M5317TDX user guide.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Copyright © 2003-2007, Nortel Networks
.
Action
Set the switch on the bottom of the terminal for either line power
or local power.
Plug in the M5317TDX terminal.
Press and hold down the RLS and HOLD keys as the terminal
powers up.
Press MAINROM.
Press INSTALL.
Press ENGLISH or FRANCAIS for your choice of language.
Press the soft key of the TEI you want to set PHONE, DATA or X25.
Note: Dynamic TEI is only supported with firmware version 2.0
or higher.
Enter * for dynamic TEI.
Enter the TEI on the terminal keypad for static TEI.
Press OK when you have finished setting the TEIs.
Enter the phone (voice) SPID. Press OK when finished.
Enter the data SPID. Press OK when finished.
Enter the data DN. Press OK when finished.
Press HEADSET until REAR displays.
Press SIGTYPE until MER1 displays.
Press A/MU until MU-LAW displays.
Press MORE.
Press DIALPLN until NATIONAL displays.
Press EXIT.
Press NO to execute SPM.
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard
Release 5.0 20 June 2007
lists and describes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000Cs 1000

Table of Contents