Table 5 "NT8D37 IPE moduleSILC and UILC pair-terminations for
connectors A, E, K, R (12-cable configuration)" (page 33)
pair-terminations for connectors.
Table 5
NT8D37 IPE module
SILC and UILC pair-terminations for connectors A, E, K, R (12-cable configuration)
Port signals
SILC
0Tx - / 0Tx +
0T / 0R
0Rx + / 0Rx -
1Tx - / 1Tx +
1T / 1R
1Rx + / 1Rx -
2Tx - / 2Tx +
2T / 2R
2Rx + / 2Rx -
3Tx - / 3Tx +
3T / 3R
3Rx + / 3Rx -
4Tx - / 4Tx +
4T / 4R
4Rx + / 4Rx -
5Tx - / 5Tx +
5T / 5R
5Rx + / 5Rx -
6Tx - / 6Tx +
6T / 6R
6Rx + / 6Rx -
7Tx - / 7Tx +
7T / 7R
7Rx + / 7Rx -
Table 6 "NT8D37 IPE moduleSILC and UILC pair-terminations for
connectors B, F, L, S (12-cable configuration)" (page 33)
pair-terminations for connectors B, F, L, S.
Table 6
NT8D37 IPE module
SILC and UILC pair-terminations for connectors B, F, L, S (12-cable configuration)
Port signals
SILC
0Tx - / 0Tx +
0T / 0R
0Rx + / 0Rx -
1Tx - / 1Tx +
1T / 1R
1Rx + / 1Rx -
Copyright © 2003-2007, Nortel Networks
.
UILC
Pairs
26 / 1
W-BL / BL-W
27 / 2
W-O / O-W
28 / 3
W-G / G-W
29 / 4
W-BR / BR-W
30 / 5
W-S / S-W
31 / 6
R -BL / BL-R
32 / 7
Rx-O / O-R
33 / 8
R -G / G-R
34 / 9
R-BR / BR-R
35 / 10
R-S / S-R
36 / 11
BK-BL / BL-BK
37 / 12
BK-O / O-BK
38 / 13
BK-G / G-BK
39 / 14
BK-BR / BK-BR
40 / 15
BK-S / S-BK
41 / 16
Y-BL / BL-Y
UILC
Pairs
26 / 1
W-BL / BL-W
27 / 2
W-O / O-W
28 / 3
W-G / G-W
29 / 4
W-BR / BR-W
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard
Release 5.0 20 June 2007
Installing ISDN BRI hardware for line applications 33
I/O panel connectors
Pair color
A
s
lot
0
I/O panel connectors
Pair color
B
lot
shows
E
K
R
s
slo
slo
t 4
t 8
lot
12
shows
F
L
S
s
slo
slo
s
lot
t 5
t 9
1
13
Card
port
0
1
2
3
4
5
6
7
Card
port
0
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000Cs 1000

Table of Contents