Table 2-22
Variable
ef6000SysOperStatus
ef6000SysState
ef6000SysAdmStatus
(read-write)
Field Replaceable Unit (FRU) Group
Table 2-23
Variable
ef6000FruCode
ef6000FruPosition
ef6000FruStatus
ef6000FruPartNumber
System Group Variables (cont'd)
Provides:
The current operational status of the director. The values are defined as
follows: operational (1), redundant-failure (2), minor-failure (3), major-failure
(4), not-operational (5).
If the edOperStatus of the director is operational, the director is in one of the
four states: online(1), coming-online(2), offline(3), and going-offline(4).
The desired administrative status of the director. A management station may
place the director in a desired state by setting this object accordingly. The
desired administrative statuses are online(1) and offline(2). Online means
setting the director to be accessible by an external Fibre Channel port, and
offline means setting the director to be inaccessible.
FRU Group Table Variables
Provides:
Field replaceable unit. A hardware component of the product that is replaceable
as an entire unit. Each module defined in this MIB has a fixed FRU code. The
values are defined as follows: fru-bkplane(1) - backplane; fru-ctp(2) - control
processor card; fru-sbar(3) - serial crossbar; fru-fan2(4) - center fan module;
fru-fan(5) - fan module; fru-power(6) - power supply module; fru-reserved(7) -
reserved (not used); fru-glsl(8) - longwave, single-mode, LC connector, 1 Gig;
fru-gsml(9) - shortwave, multi-mode, LC connector, 1 Gig; fru-gxxl(10) - mixed,
LC connector, 1 Gig; fru-gsfl(11) - SFO pluggable, 1Gig; fru-gsf2(12) - SFO
pluggable, 2 Gig; fru-glsr(13) - longwave, single-mode, MT-RJ connector, 1 Gig;
fru-gsmr(14) - shortwave, multi-mode, MT-RJ connector, 1 Gig; fru-gxxr(15) -
mixed, MT-RJ connector, 1 Gig; fru-fint1(16) - F_Port, internal, 1 Gig.
Position of the module.
Operational status of the module. The active(1) state indicates that the current
module is active. The backup(2) state indicates that the backup module is used.
The update-busy (3) state indicates that the module is in the updating process.
The failed(4) state indicates that the current module is failed.
Part number of the module.