HP Surestore 64 - Director Switch Manual page 27

Snmp support manual
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Table 2-3
Object
ConnUnitNumports
ConnUnitState
ConnUnitStatus
ConnUnitProduct
ConnUnitSn
ConnUnitUpTime
ConnUnitUrl
ConnUnitDomainId
Connectivity Unit Table (cont'd)
Provides
The port capacity of 32 is returned for the director.
The overall state of the connectivity unit is returned. unknown(1), online(2),
offline(3).
The mapping of director on-line states to MIB ConnUnitStates:
Director
MIB
online
online state(2)
going-offline
offline state(3)
offline
offline state(3)
coming-online
online state(2).
unknown(1) is returned when the link between the HP EFC Server and the
director is down.
The overall status of the connectivity unit is returned. unknown(1), unused(2),
ok(3), warning(4) – needs attention, and failed(5).
The mapping of director operational status values to MIB ConnUnitStatus:
Director
MIB
operational
ok(3)
degraded
warning(4)
failed
failed(5)
unknown(1) is returned when the link between the HP EFC Server and the
director is down.
Product name is returned.
The serial number for this connectivity unit.
The total time the link between the HP EFC Server and the switch or director
has been up.
http://[EFCM IP addr]/cgi-bin/launch.exe?[product netaddr] where [product
netaddr] is either the host name of the switch or the IP addr of the director. The
form of the address depends upon how the switch was added to the HP EFC
Manager. If it was added by Name then the name will appear otherwise the IP
address will appear.
If HP EFC Manager Version 1.1 or higher is installed on the PC, accessing this
URL from a browser will start the HP EFC Manager application.
The value 0xFFCCdd is returned where dd is the domain id of the director.
21