Table 2-20
Variable
Provides:
Medium
FC-0 medium of the F_Port.
TxType
FC-0 transmitter type of the F_Port.
Distance
FC-0 distance range of the F_Port transmitter.
Capability Group Table
The Fccfportcaptable displays the capabilities of the F_Port within the fabric element.
Table 2-21
Variable
Provides
CapModuleIndex
Module index.
FxPortIndex
Port index.
FC-PHVersionHigh Highest or most recent version of FC-PH that the FxPort is capable of supporting.
FC-PHVersLow
Lowest or earliest version of FC-PH that the F_Port is capable of supporting.
BBCreditMax
Maximum number of receive buffers available for holding a class 1 connect-request, or class 2 or
class 3 frames from the attached N_Port.
BBCreditMin
Minimum number of receive buffers available for holding a class 1 connect-request, or class 2 or
class 3 frames from the attached N_Port.
RxDataFldSzMax
Maximum size in bytes of the data field in a frame that the F_Port is capable of receiving from its
attached N_Port.
RxDataFldSzMin
Minimum size in bytes of the data field in a frame that the F_Port is capable of receiving from its
attached N_Port.
Cos
Value indicating the set of classes of service the F_Port is capable of supporting.
Intermix
Flag indicating if the F_Port is capable of supporting the intermixing of class 2 and class 3
frames during a class 1 connection. This flag is only valid if the port is capable of supporting
class 1 service. Fixed at no(2).
StackedConMode
Value indicating the mode of stacked connect request that the F_Port is capable of supporting.
Fixed at none(1).