Troubleshooting
Current Area Messages
Probable Cause
The supplied current of the SFP transceiver is outside of a factor set normal range,
indicating a possible hardware failure.
Recommended Action
If the current rises above the high boundary, you must replace the SFP.
Messages
Message
Description
Troubleshooting
Message
Description
Troubleshooting
Message
Description
Troubleshooting
Message
Fabric Watch Version 3.1.x/4.1.x User Guide
This message is informational. Respond to this message as is appropriate to
the particular policy of the end-user installation.
FW-CHANGED, 4, sfpCrnt<element index> (Sfp Current <element
index>) value has changed, current value: <value> mA. (info)
Explains that the value of SFP current has changed. Provides the new value.
This message is informational. Respond to this message as is appropriate to
the particular policy of the end-user installation.
FW-EXCEEDED, 3, sfpCrnt<element index> (Sfp Current <element
index>) exceeded boundary, current value: <value> mA. (faulty)
Explains that the value of SFP current has risen above or fallen below the
acceptable range. Provides the new value.
This is an informational message. Respond to this message as is appropriate
to the particular policy of the end-user installation.
FW-BELOW, 3, sfpCrnt<element index> (Sfp Current <element index>) is
below low boundary, current value: <value> mA. (faulty)
Explains that the value of SFP current has fallen below the low boundary.
Provides the new value.
This is an informational message. Respond to this message as is appropriate
to the particular policy of the end-user installation.
FW-ABOVE, 3, sfpCrnt<element index> (Sfp Current <element index>) is
above high boundary, current value: <value> mA. (faulty)
Responding to Fabric Watch Messages
123