Sfp-Class Threshold Defaults - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks fabric watch v3.1.x/4.1.x user guide (aa-rtsgc-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Table 22
Table 22: SFP-Class Threshold Defaults
Temperature
Receive Power
Transmit
Power
Current
Supply
Voltage
Fabric Watch Version 3.1.x/4.1.x User Guide
provides default settings for areas in the SFP class.
Area
Description
Monitors
SFP(s)
Temperature
in Celsius
Monitors
receive power
in µwatts
Monitors
transmit
power in
µwatts
Monitors SFP
current in
mamps
Measures the
amount of
supplied
voltage to the
SFP
Default
Threshold
Default Alarm
Settings
Settings
Unit: C
Changed: 0
Time Base:
Exceeded: 0
Low: -10
Below: 1
High: 85
Above: 1
Buffer: 3
In-between: 1
Unit: µWatts
Changed: 0
Time Base:
Exceeded: 0
Low: 0
Below: 1
High: 5000
Above: 1
Buffer: 25
In-between: 0
Unit: µWatts
Changed: 0
Time Base:
Exceeded: 0
Low: 0
Below: 1
High: 5000
Above: 1
Buffer: 25
In-between: 0
Unit: mA
Changed: 0
Time Base:
Exceeded: 0
Low: 0
Below: 1
High: 50
Above: 1
Buffer: 1
In-between: 0
Unit: mV
Changed: 0
Time Base:
Exceeded: 0
Low: 3150
Below: 1
High: 3600
Above: 1
Buffer: 10
In-between: 0
Default Threshold Values
Threshold
State
Informative
Faulty
Faulty
Faulty
Normal
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Faulty
Normal
Informative
Informative
Faulty
Faulty
Faulty
Normal