When you run the iSCSI Initiator manually, new devices have a status of Inactive. You must log on to
the appropriate targets for your host. Remember that each library has at least two devices and you
must log onto each one separately. If the emulation type you have selected allows more drives, there
will be a target device for each drive.
NOTE:
If you are using mutual CHAP authentication, you set up the details when you log on to the target.
If you are using a dual port configuration, there will be two IP addresses in separate subnets for each
device. The iSCSI initiator will return both IP addresses as possible login addresses. If the default
choice does not work you can select a specific port. High Availability dual ports return a single IP
address. See also
"Dual network
ports" on page 37.
Figure 29 Targets tab (iSCSI)
We recommend that you also select the Automatically restore this connection when the system boots
option in the Log On... dialog.