Trace Logs; Auto Save On Crash Or Rollover - Dell PowerEdge M IO Aggregator Command Reference Manual

Mxl 10/40gbe switch io module ftos command reference guide, ftos 8.3.16.1
Hide thumbs Also See for PowerEdge M IO Aggregator:
Table of Contents

Advertisement

Figure 22-3. Taking a Stack Unit Offline
FTOS#offline stack-unit 2
Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
5w6d12h: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - stack unit offline
5w6d12h: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Tengig 2/1-48
FTOS#5w6d12h: %STKUNIT1-S:CP %IFMGR-1-DEL_PORT: Removed port: Tengig 2/1-48
2. Use the
show system brief
Figure 22-4. Verifying the Offline/Online Status of a Stack Unit
FTOS#show system brief | no-more
Stack MAC : 00:01:e8:00:ab:03
--
Stack Info
Unit
UnitType
------------------------------------------------------------------------------------
0
Member
1
Management
2
Member
3
Member
4
Member
5
Member
FTOS#

Trace Logs

In addition to the syslog buffer, the Dell Force10 operating software (FTOS) buffers trace messages which
are continuously written by various FTOS software tasks to report hardware and software events and status
information. Each trace message provides the date, time, and name of the FTOS process. All messages are
stored in a ring buffer and can be saved to a file either manually or automatically upon failover.

Auto Save on Crash or Rollover

Exception information on Master or Standby units is stored in the flash:/TRACE_LOG_DIR directory.
This directory contains files that save trace information when there has been a task crash or timeout.
On a Master unit, you can reach the TRACE_LOG_DIR files by file transfer protocol (FTP) or by using
the
command from the flash://TRACE_LOG_DIR directory.
show file
On a Standby unit, you can reach the TRACE_LOG_DIR files only by using the
the flash://TRACE_LOG_DIR directory.
Note: Non-management Member units do not support this functionality.
command from EXEC Privilege mode to confirm offline status
--
Status
ReqTyp
not present
online
I/O-Aggregator
not present
not present
not present
not present
CurTyp
Version
I/O-Aggregator
8-3-17-38
(Figure
22-4).
Ports
56
command from
show file
Debugging and Diagnostics | 251

Advertisement

Table of Contents
loading

Table of Contents