Software show Commands

Use the show version and show system stack-unit 0 commands as a part of troubleshooting an
Aggregator's software configuration in a standalone or stacking scenario.
Table 22-1. Software show Commands
Command
show version
show system stack-unit 0
Figure 22-1. show version Command Example
FTOS#show version
Dell Force10 Real Time Operating System oftware
Dell Force10 Operating System Version: 1.0
Dell Force10 Application Software Version: E8-3-17-24
Copyright (c) 1999-2012 by Dell Inc. All Rights Reserved.
Build Time: Thu Jul 5 11:20:28 PDT 2012
Build Path: /sites/sjc/work/build/buildSpaces/build05/E8-3-17/SW/SRC/Cp_src/Tacacs
st-sjc-m1000e-3-72 uptime is 17 hour(s), 1 minute(s)
System image file is "st-sjc-m1000e-3-c2"
System Type: I/O-Aggregator
Control Processor: MIPS RMI XLP with 2147483648 bytes of memory.
256M bytes of boot flash memory.
1 34-port GE/TE (XL)
56 Ten GigabitEthernet/IEEE 802.3 interface(s)
248
|
Debugging and Diagnostics
Description
Display the current version of FTOS software running on an Aggregator.
Display software configuration on an Aggregator in stacking mode.