THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to two
3" (76mm) co-linear aluminium flex running the
full length of the chimney. See the Venting
Arrangements on next page for minimum and
maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Flue Adaptor
Alternate Approved Caps
980
Vertical Termination Cap
991
High Wind Cap
923GK 3" Co-linear Adapter with flashing
FPI Cabinet and/or Flat Wall Mantles
may be used in these applications
ensuring that clearances to com-
bustibles are maintained.
FPI P36-3 Zero Clearance Direct Vent Gas Fireplace
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
Masonry chimneys may take various contours which the flexible liner will accommodate.
However, keep the flexible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
INSTALLATION