FPI P36-NG3 Owners & Installation Manual page 28

P36 zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
The P36 is approved for a 40 ft. straight vertical, with rigid pipe vent systems
for Propane and Natural Gas, as per the diagram 1.
The shaded area in the diagram 1 shows all allowable combinations of straight
vertical and offset to vertical terminations with rigid pipe vent systems for
Propane and Natural Gas. Maximum two 45
Vent must be supported at offsets.
Firestops are required at each floor level and whenever passing
through a wall.
Maintain clearances to combustibles.
28
o
elbows allowed.
Diagram 1
FPI P36-3 Zero Clearance Direct Vent Gas Fireplace